- Industrial Standard 2"×1" Package
- Wide 2:1 Input Voltage Range
- Fully Regulated Output Voltage
- I/O Isolation 4200VAC with Reinforced Insulation, rated for 300Vrms Working Voltage
- Low Leakage Current
- Operating Ambient Temp. Range -40℃ to +85℃
- No Min. Load Requirement
- Under-voltage, Overload/Voltage and Short Circuit Protection
- EMI Emission EN 55011 Class A Approved
- Medical EMC Standard with 4th Edition of EMI EN 55011 and EMS EN 60601-1-2 Approved
- Medical Safety with 2xMOPP per 3.2 Edition of IEC/EN 60601-1 & ANSI/AAMI ES60601-1 Approved with CE Marking
The MINMAX MKW15M series is a range of high performance 15W medical approved DC-DC converter within encapsulated 2’’x1’’ package which specifically design for medical applications. There are 21 models available for input voltage of 12, 24, 48VDC with wide 2:1 input range and fixed output voltage. The I/O isolation is specified for 4200VAC with reinforced insulation, which rated for 300Vrms working voltage. Further features include under-voltage, overload, over voltage, short circuit protection, no min. load requirement, EMI emission EN 55011 class A approved, low I/O leakage current 5μA max. and operating ambient temp. range by -40℃ to 85℃ by high efficiency up to 90%.
MKW15M series conform to 4th edition medical EMC standard, medical safety with 2xMOPP (Means Of Patient Protection) per 3.2 Edition of IEC/EN 60601-1 & ANSI/AAMI ES 60601-1 approved. The MKW15M series offer the best solution for demanding applications in medical instrument requesting a certified supplementary and reinforced insulation system to comply with latest medical safety approval for 2xMOPP requirement.
Output Voltage Accuracy | ±1.0% max. | ||
Line Regulation | ±0.5% max. | ||
Load Regulation | Single | ±0.5% max. | |
Dual | ±1.0% max. | ||
Ripple & Noise (20MHz) | 5V 5.1V | 50mVp-p typ. | |
24V | 150mVp-p typ. | ||
others | 100mVp-p typ. | ||
Efficiency | Up to 90% | ||
I/O Isolation Voltage | 4200VAC min. (Reinforced Insulation) | ||
I/O Isolation Capacitance | 80pF typ. | ||
Leakage Current | <5µA | ||
Operating Ambient Temp. Range | -40°C to +85°C (See Derating Curve) | ||
Short Circuit Protection | Continuous (Auto. Recovery) | ||
Case Material | Plastic (UL94V-0 rated) | ||
Safety Approval | 2xMOPP per 3rd Edition of IEC/EN 60601-1 & ANSI/AAMI ES60601-1, CB Report, CE Marking |
- Lise-Meitner-Straße 3, D-64560 Riedstadt-Wolfskehlen
- weborder@emtron.de
- +49(0)6158-8285-0
- +49(0)6158-8285-155
- Robert-Bosch-Str. 25, 63225 Langen, Germany
- markus.mueller@eu.kagafei.com
- +49 (0) 6103 690 390
- +49 (0) 173 700 49 68
- Warwitzstrasse 9 5020 Salzburg
- austria@texim-europe.com
- +43 (0)662 216 026
- +43 (0)662 216 026-66
- Sdr. Jagtvej , 2970 Hørsholm
- nordic@texim-europe.com
- +45 88 20 26 30
- +45 88 20 26 39
- Robert-Bosch-Str. 25, 63225 Langen, Germany
- markus.mueller@eu.kagafei.com
- +49 (0) 6103 690 390
- +49 (0) 173 700 49 68
- Lise-Meitner-Straße 3, D-64560 Riedstadt-Wolfskehlen
- weborder@emtron.de
- +49(0)6158-8285-0
- +49(0)6158-8285-155
- Robert-Bosch-Str. 25, 63225 Langen, Germany
- markus.mueller@eu.kagafei.com
- +49 (0) 6103 690 390
- +49 (0) 173 700 49 68
- Bahnhofstrasse 92, 25451 Quickborn
- germany@texim-europe.com
- +49 (0)4106 627 07-0
- +49 (0)4106 627 07-20
- Martin-Kollar-Strasse 9, 81829 München
- muenchen@texim-europe.com
- +49 (0)89 436 086-0
- +49 (0)89 436 086-19
- Martin-Kollar-Strasse 9 , 81829 München
- italy@texim-europe.com
- +49 (0)89 436 086-0
- +49 (0)89 436 086-19
- Elektrostraat 17 NL-7483 PG Haaksbergen
- nl@texim-europe.com
- +31 (0)53 573 33 33
- +31 (0)53 573 33 30
Comparison | ECAD | Model Number | Output Power | Input Voltage (VDC) | Output Voltage (VDC) | Output Current (mA) | Efficiency | Output Regulation | I/O Isolation | Package Type |
---|