AYM-60 シリーズ
60W AC-DCパワーモジュール
製品の特徴
  • ポッティング、プラスティックケース、シャーシ&DINレールマウント
  • ユニバーサル入力電圧範囲 85~264VAC, 47~440Hz
  • 強化絶縁耐圧4000VAC
  • 動作周囲温度範囲-40℃ to +80℃
  • 過電流/過電圧/短絡保護機能
  • EMIエミッションフィルタ内蔵、EN 55011/32 Class B 準拠
  • EMSイミュニティフィルタ内蔵、EN 61000-4-2,3,4,5,6,8,11準拠
  • 医療用機器EMC規格EMI EN 55011 & EMS EN 60601-1-2第4版準拠
  • 医療機器安全規格IEC/EN 60601-1 & ANSI/AAMI ES 60601-1第3.2版(2xMOPP)認証取得
  • 産業用制御機器安全規格UL 508認証取得(選択可能)
  • UL/cUL/IEC/EN 62368-1(60950-1)認証取得 & CEマーキング
製品説明

Introducing the MINMAX AYM-60 series – a range of fully encapsulated AC-DC power modules designed to deliver superior performance, safety, and reliability. Engineered to excel across diverse applications, these high-performance products boast an impressive extended operating temperature range of -40℃ to +80℃, ensuring optimal functionality in challenging environments.
With a universal input voltage of 85-264VAC and robust safety approvals, including compliance with UL/IEC/EN standards for medical safety and UL 508 listing, the AYM-60 series is poised for seamless integration into products targeting global markets. These power supply modules have also received the esteemed EMI Emission EN 55011/32 Class B approval, attesting to their adherence to stringent electromagnetic interference standards.
In alignment with ISO 14971 Medical Device Risk Management, the AYM-60 series undergoes a thorough risk assessment process. This ensures that the power modules not only meet rigorous performance criteria but also align with the highest safety benchmarks outlined in ISO 14971. By seamlessly incorporating the AYM-60 series into your medical devices, you not only leverage state-of-the-art technology but also ensure compliance with risk management protocols.

製品仕様
Input Voltage Range 85 - 264VAC (120 - 370VDC) / 47 - 440Hz
Output Voltage Accuracy ±1.0% typ.
Line Regulation ±0.2% typ.
Load Regulation ±0.5% typ.
Ripple & Noise (20MHz) 5.1V  2.0%Vp-p of Vo typ.
others  1.0%Vp-p of Vo typ.
Efficiency Up to 88%
I/O Isolation Voltage 4000VAC min. (Reinforced Insulation)
Operating Temp. Range -40°C to +80°C (See Power Derating)
Over Load Protection >105% min., Hiccup (Auto. Recovery)
Short Circuit Protection Continuous (Auto. Recovery)
Case Material Plastic (UL94V-0 rated)
Safety Approval UL/cUL/IEC/EN 62368-1(60950-1) , UL508, 2xMOPP per 3rd Edition of IEC/EN 60601-1 & ANSI/AAMI ES60601-1, CB-Report, CE Marking
Contact local distributor for quote

Comparison ECAD Model Number Output Power Input Voltage (VAC) Output Voltage (VDC) Output Current (mA) Efficiency I/O Isolation
Datasheet