- 業界標準 DIP-24 パッケージ
- ワイド入力範囲 2:1
- 安定化出力
- 強化絶縁耐圧 5000VAC、動作電圧 250Vrms
- 8mm 沿面距離と空間距離
- 低漏洩電流
- 動作周囲温度範囲 -40 ℃ to 95 ℃
- 最低負荷要求なし
- 入力低電圧/過電流/過電圧/短絡保護機能
- 伝導電磁妨害フィルタ内蔵、EN 55011 Class A 準拠
- 医療用機器EMC規格EMI EN 55011 & EMS EN 60601-1-2第4版準拠
- 医療機器安全規格IEC/EN 60601-1 & ANSI/AAMI ES 60601-1第3.2版(2×MOPP)認証取得、CEマーキング
Introducing the MINMAX MIW06M series – an innovative range of high-performance 6W medical-approved DC-DC converters encapsulated in a DIP-24
package, purposefully designed for medical applications. With an extensive selection of 15 models supporting input voltages of 12, 24, and 48VDC,
featuring a wide 2:1 input range and fixed output voltage, this series ensures adaptability to diverse medical device specifications.
The MIW06M series boasts an I/O isolation specified for 5000VAC with reinforced insulation, rated for a reliable 250Vrms working voltage. Advanced
features include under-voltage, overload, over-voltage, and short-circuit protection, along with no minimum load requirement, conducted EMI EN 55011
class A approval, low I/O leakage current of 2µA max, and an operating ambient temperature range from -40℃ to +95℃ without derating, achieved through
high efficiency up to 89%.
Aligned with the 4th edition medical EMC standard, the MIW06M series holds medical safety approval with 2xMOPP (Means Of Patient Protection) per the
3.2 Edition of IEC/EN 60601-1 & ANSI/AAMI ES 60601-1, incorporating an 8mm creepage and clearance.
In adherence to ISO 14971 Medical Device Risk Management, the MIW06M series undergoes a thorough risk assessment process. This ensures not only
compliance with high-performance standards but also alignment with the stringent safety benchmarks outlined in ISO 14971. Elevate your medical devices
with the MINMAX MIW06M series – the integration of advanced technology, safety, performance, and Medical Device Risk Management Report Acquisition.
Output Voltage Accuracy | ±1.0% max. | |
Line Regulation | ±0.5% max. | |
Load Regulation | Single | ±0.5% max. |
Dual | ±1.0% max. | |
Ripple & Noise (20MHz) | 70mVp-p typ. | |
Efficiency | Up to 89% | |
I/O Isolation Voltage | 5000VAC min. (Reinforced Insulation) | |
I/O Isolation Capacitance | 40pF max. | |
Operating Ambient Temp. Range | -40℃ to +95℃ (See Derating Curve) | |
Short Circuit Protection | Continuous (Auto. Recovery) | |
Case Material | Plastic (UL94V-0 rated) | |
Safety Approval | 2xMOPP per 3rd Edition of IEC/EN 60601-1 & ANSI/AAMI ES60601-1, CB-Report, CE Marking |
- 702 台南市南区中華西路一段77号
- sales@minmax.com.tw
- (+886)6-2923150#1119
- (+886)6-2923149
- Lise-Meitner-Straße 3, D-64560 Riedstadt-Wolfskehlen
- weborder@emtron.de
- +49(0)6158-8285-0
- +49(0)6158-8285-155
- Robert-Bosch-Str. 25, 63225 Langen, Germany
- markus.mueller@eu.kagafei.com
- +49 (0) 6103 690 390
- +49 (0) 173 700 49 68
- Warwitzstrasse 9 5020 Salzburg
- austria@texim-europe.com
- +43 (0)662 216 026
- +43 (0)662 216 026-66
- Sdr. Jagtvej , 2970 Hørsholm
- nordic@texim-europe.com
- +45 88 20 26 30
- +45 88 20 26 39
- Robert-Bosch-Str. 25, 63225 Langen, Germany
- markus.mueller@eu.kagafei.com
- +49 (0) 6103 690 390
- +49 (0) 173 700 49 68
- Lise-Meitner-Straße 3, D-64560 Riedstadt-Wolfskehlen
- weborder@emtron.de
- +49(0)6158-8285-0
- +49(0)6158-8285-155
- Robert-Bosch-Str. 25, 63225 Langen, Germany
- markus.mueller@eu.kagafei.com
- +49 (0) 6103 690 390
- +49 (0) 173 700 49 68
- Bahnhofstrasse 92, 25451 Quickborn
- germany@texim-europe.com
- +49 (0)4106 627 07-0
- +49 (0)4106 627 07-20
- Martin-Kollar-Strasse 9, 81829 München
- muenchen@texim-europe.com
- +49 (0)89 436 086-0
- +49 (0)89 436 086-19
- Martin-Kollar-Strasse 9 , 81829 München
- italy@texim-europe.com
- +49 (0)89 436 086-0
- +49 (0)89 436 086-19
- Elektrostraat 17 NL-7483 PG Haaksbergen
- nl@texim-europe.com
- +31 (0)53 573 33 33
- +31 (0)53 573 33 30
Comparison | ECAD | Model Number | Output Power | Input Voltage (VDC) | Output Voltage (VDC) | Output Current (mA) | Efficiency | Output Regulation | I/O Isolation | Package Type |
---|