- 全塑料封装外壳 : PCB插件式、基座式与DIN-Rail轨道式
- 国际通用输入范围:85~264VAC, 47~440Hz
- 加强型绝缘,隔离耐压4000VAC
- 工作环境温度范围:-40℃至+80℃
- 具备输出过电流、输出过电压、输出短路保护机制
- 内含电磁干扰性(EMI)滤波电路,符合EN55011/32 Class B
- 内含电磁耐受性(EMS)滤波电路,符合EN61000-4-2,3,4,5,6,8
- 符合第4版医疗EMC标准EMI EN55011 & EMS EN60601-1-2
- 符合第3.2版医疗安规IEC/EN 60601-1 & ANSI/AAMI ES60601-1(2×MOPP)认证
- 符合国际工业安规UL508(选项)
- 符合国际安规UL/cUL/IEC/EN 62368-1(60950-1) 认证与CE标志
Introducing the innovative MINMAX AJM-24 series, a range of fully encapsulated AC-DC power modules designed for high performance in diverse
applications. With an impressive extended operating temperature range of -40℃ to +80℃, these modules ensure reliable functionality in challenging
environments. Boasting a universal input voltage of 85-264VAC and holding essential safety approvals such as UL/IEC/EN, including compliance with
medical safety standards and UL 508 listing, the AJM-24 series is poised for integration into products destined for global markets.
Furthermore, these power modules adhere to stringent EMI Emission standards, having received EN 55011/32 Class B approval. This exceptional feature
makes them an ideal choice for applications in commercial, medical, and industrial electronic equipment, particularly those with space constraints.
In alignment with ISO 14971 Medical Device Risk Management standards, the AJM-24 series undergoes a meticulous risk assessment process. This
ensures that the power modules not only meet the highest quality and safety benchmarks but also adhere to the stringent risk management protocols
outlined in ISO 14971.
Input Voltage Range | 85 - 264VAC (120 - 370VDC) / 47 - 440Hz | ||
Output Voltage Accuracy | ±2.0% typ. | ||
Line Regulation | ±0.5% typ. | ||
Load Regulation | Single | ±0.5% typ. | |
Dual | ±2.5% typ. | ||
Ripple & Noise (20MHz) | 5V | 1.5%Vp-p of Vo typ. | |
others | 1.0%Vp-p of Vo typ. | ||
Efficiency | Up to 84% | ||
I/O Isolation Voltage | 4000VAC min. (Reinforced Insulation) | ||
Operating Temp. Range | -40°C to +80°C (See Power Derating) | ||
Over Load Protection | >105% min., Hiccup (Auto. Recovery) | ||
Short Circuit Protection | Continuous (Auto. Recovery) | ||
Case Material | Plastic (UL94V-0 rated) | ||
Safety Approval | UL/cUL/IEC/EN 62368-1(60950-1) , UL508, 2xMOPP per 3rd Edition of IEC/EN 60601-1 & ANSI/AAMI ES60601-1, CB-Report, CE Marking |
- 702台南市南区中华西路一段77号
- sales@minmax.com.tw
- (+886)6-2923150#1119
- (+886)6-2923149
- Lise-Meitner-Straße 3, D-64560 Riedstadt-Wolfskehlen
- weborder@emtron.de
- +49(0)6158-8285-0
- +49(0)6158-8285-155
- Robert-Bosch-Str. 25, 63225 Langen, Germany
- markus.mueller@eu.kagafei.com
- +49 (0) 6103 690 390
- +49 (0) 173 700 49 68
- Warwitzstrasse 9 5020 Salzburg
- austria@texim-europe.com
- +43 (0)662 216 026
- +43 (0)662 216 026-66
- Sdr. Jagtvej , 2970 Hørsholm
- nordic@texim-europe.com
- +45 88 20 26 30
- +45 88 20 26 39
- Robert-Bosch-Str. 25, 63225 Langen, Germany
- markus.mueller@eu.kagafei.com
- +49 (0) 6103 690 390
- +49 (0) 173 700 49 68
- Lise-Meitner-Straße 3, D-64560 Riedstadt-Wolfskehlen
- weborder@emtron.de
- +49(0)6158-8285-0
- +49(0)6158-8285-155
- Robert-Bosch-Str. 25, 63225 Langen, Germany
- markus.mueller@eu.kagafei.com
- +49 (0) 6103 690 390
- +49 (0) 173 700 49 68
- Bahnhofstrasse 92, 25451 Quickborn
- germany@texim-europe.com
- +49 (0)4106 627 07-0
- +49 (0)4106 627 07-20
- Martin-Kollar-Strasse 9, 81829 München
- muenchen@texim-europe.com
- +49 (0)89 436 086-0
- +49 (0)89 436 086-19
- Martin-Kollar-Strasse 9 , 81829 München
- italy@texim-europe.com
- +49 (0)89 436 086-0
- +49 (0)89 436 086-19
- Elektrostraat 17 NL-7483 PG Haaksbergen
- nl@texim-europe.com
- +31 (0)53 573 33 33
- +31 (0)53 573 33 30
Comparison | ECAD | Model Number | Output Power | Input Voltage (VAC) | Output Voltage (VDC) | Output Current (mA) | Efficiency | I/O Isolation |
---|